Série Beta 80K-5G
Caractéristiques Pincipales
• 13 A par chaîne, capacité de surcharge de 150% DC.
• 9 MPPT individuels, perte de production plus faible.
• Algorithme logique efficace, plus de 99% max.
• Surveillance de la chaîne du module FV, temps plus court.
• Fonction de numérisation IV intelligente à distance et locale.
• Technologie de répression actuelle des fuites.
• Mode de travail Volt-watt intégré.
• Alarme inverse d'entrée DC.
• Fonction anti-PID en option intégrée.
• Fonction de compensation de puissance réactive.
SOLUTIONS
+PENSER +CONSTRUIRE
Spécifications
| MODÉLE | Beta 80K-5G |
|---|---|
| INPUT DC | |
| Maximum Recommended DC Input Power (kW) | 112 |
| DC Input Voltage (V) | 1100 |
| Nominal DC Voltage (V) | 600 |
| Output Voltage (V) | 200 |
| MPPT Operating Voltage Range (V) | 180 - 1000 |
| Full Load MPP Voltage Range (V) | 505 - 850 |
| Maximum Input Current (A) | 26*8 |
| Maximum Short-Circuit Current for each MPPT (A) | 40*8 |
| MPPT Number / Maximum Input Strings Number | 8/A:2; B:2; C:2; D:2; E:2; F:2; G:2; H:2 |
| OUTPUT AC | |
| Rated Output Power (kW) |
80 |
| Maximum Apparent Output Power (kVA) | 88 |
| Maximum Output Power (kW) | 88 |
| Nominal Grid Voltage (V) | 230 / 400 |
| Nominal Grid Frequency (Hz) | 50 / 60 |
| AC Grid Frequency Range (Hz) | 45 ~ 55 / 55 ~ 60 |
| Operation Phases | Three |
| Nominal Grid Output Current (A) | 115.5 |
| Output Current (A) | 133.7 |
| Power Factor (nominal output power) | 0.8 Leading... 0.8 Lagging |
| THDi (nominal output power) | < 3% |
| DC Injection Current | 0.5% In |
| EFFICIENCY | |
| Maximum Efficiency | 99.0% |
| EU Efficiency | 98.4% |
| MPPT Efficiency | 99.5% |
| PROTECTION | |
| Islanding Protection |
Yes |
| DC Reverse-Polarity Protection | Yes |
| Isolation Resistance Monitoring | Yes |
| Residual Current Detection | Yes |
| DC Overvoltage Protection | Type II / Type I + II |
| AC Overvoltage Protection | Type II |
| Grid Monitoring | Yes |
| Strings Monitoring | Yes |
| I / V Curve Scanning | Yes |
| Anti-PID Function | Yes |
| Integrated AFCI (DC arc-fault circuit protection) | Yes |
| Integrated DC Switch | Yes |
| Integrated AC Switch | Optional |
| GENERAL DATA | |
| Dimensions (mm) |
1050W*567H*286.5D |
| Weight (kg) | < 85 |
| Topology | Transformerless |
| Self Consumption (night) | < 2W |
| Operating Ambient Temperature Range | -25 ~ 60°C |
| Relative Humidity | 0 ~ 100% |
| IP Protection | IP66 |
| Noise Emission (typical) | ≤ 55 dBA |
| Cooling Concept | Intelligent redundancy fan |
| Maximum Operation Altitude | 4000 m |
| STANDARDS | |
| Grid Connection Standard |
EN50549, G99, AS4777.2-2015, VDE0126-1-1, IEC62727, VDE4105-2018, IEE1547, UL1741SA |
| Safety / EMC Standard | IEC62109-1/-2, NB/T32004-2018, EN61000-6-1, EN61000-6-3, UL1741, FCC |
| FEATURES | |
| DC Connection | MC4 |
| AC Connection | OT Terminal connectors |
| Display | LCD, 2 × 20 Z. |
| Communication Connections | RS485 / PLC (optional) |
| Warranty | 5 / 10 / 15 / 20 Years |
Les caractéristiques techniques du produit sont susceptibles d'être modifiées sans préavis.